ICM7249 meter equivalent, micro-power event/hour meter.
* Hour Meter Requires Only 4 Parts Total
* Micropower Operation: < 1µA at 2.8V (Typ)
* 10 Year Operation On One Lithium Cell. 21/2 Year Battery Life with Disp.
The ICM7249 typically draws 1µA during active timing or counting, due to Intersil’ special low-power design techniques..
The ICM7249 Timer/Counter is intended for long-term battery-supported industrial applications. The ICM7249 typically draws 1µA during active timing or counting, due to Intersil’ special low-power design techniques. This allows more than 10 years of c.